Water Filtration Performance Data & Contaminant Reduction

Freedom Water Systems uses advanced filtration media technologies designed to reduce a wide range of contaminants and water-quality concerns. The performance data below includes results for PFAS compounds such as PFOA and PFOS, chlorine and chloramine, volatile organic compounds (VOCs), emerging contaminants, pharmaceuticals, fluoride, and other substances.

Results shown are based on laboratory testing under the conditions indicated in the source performance data. Actual performance can vary based on water chemistry, contaminant concentration, flow rate, system configuration, media age, and household water use.

Where an NSF/ANSI standard or historical NSF protocol is referenced, the reference identifies the testing method or performance basis used in the source data. It should not be interpreted as a statement that every Freedom Water Systems product is independently NSF certified unless certification is specifically stated for that product.

PFAS Reduction Data - Historical NSF P473 Test Basis

About this PFAS testing: NSF Protocol P473 was developed as a testing method for PFOA and PFOS reduction and was later incorporated into NSF/ANSI Standards 53 and 58. References to P473 were subsequently replaced by the applicable NSF/ANSI 53 or 58 standards.

Source: NSF - Forever Chemicals and the Advancement of Filtration Standards

The results below reflect the historical P473 test basis and should not be interpreted as demonstrating compliance with today's EPA drinking-water limits. The EPA currently sets enforceable Maximum Contaminant Levels of 4.0 parts per trillion (ppt) for PFOA and 4.0 ppt for PFOS.

Source: U.S. EPA - PFAS National Primary Drinking Water Regulation

Contaminant Influent Challenge Concentration Maximum Permissible Product Water Concentration Percent Reduction Results
Perfluorooctanoic acid (PFOA) 1.5 +/- 10% µg/L 0.07 µg/L 96% Pass - historical P473 criterion
Perfluorooctane sulfonate (PFOS) 1.5 +/- 10% µg/L 0.07 µg/L 96% Pass - historical P473 criterion

NSF/ANSI 42 - Taste & Odor

Contaminant / Parameter Challenge / Influent Product Water Percent Reduction Results
Chlorine Reduction, Free Available 2.0 mg/L <0.5 mg/L >99% Pass
Chloramine Reduction, Free Available 4.0 mg/L <0.5 mg/L >98% Pass
Particulate @ 20 micron 85% >99.99% >99.99% Pass
Microplastics 100 mg/L <1 mg/L >99%

Volatile Organic Compounds (VOCs)*

Contaminant EPA Maximum Contaminant Level (MCL) mg/L Influent Challenge (mg/L) Effluent Maximum (mg/L) Percent Reduction
Alachlor 0.002 0.05 0.001 >98%
Atrazine 0.003 0.100 0.003 >97%
Benzene 0.005 0.081 0.001 >99%
Carbofuran (Furadan) 0.04 0.19 0.001 >99%
Carbon Tetrachloride 0.005 0.078 0.0018 >98%
Chlorobenzene 0.1 0.077 0.001 >99%
Chloropicrin - 0.015 0.0002 >99%
2,4-D (Dichlorophenoxyacetic acid) 0.07 0.110 0.0017 >98%
Dibromochloropropane (DBCP) 0.0002 0.052 0.00002 >99%
o-Dichlorobenzene 0.6 0.08 0.001 >99%
p-Dichlorobenzene 0.075 0.04 0.001 >98%
1,2-Dichloroethane 0.005 0.088 0.0048 >95%
1,1-Dichloroethylene 0.007 0.083 0.001 >99%
cis-1,2-Dichloroethylene 0.07 0.17 0.0005 >99%
trans-1,2-Dichloroethylene 0.1 0.086 0.001 >99%
1,2-Dichloropropane 0.005 0.08 0.001 >99%
cis-1,3-Dichloropropylene - 0.079 0.001 >99%
Dinoseb 0.007 0.17 0.0002 >99%
Endrin 0.002 0.053 0.00059 >99%
Ethylbenzene 0.7 0.088 0.001 >99%
Ethylene Dibromide (EDB) 0.00005 0.044 0.00002 >99%
Haloacetonitriles (HAN): Bromochloroacetonitrile - 0.022 0.0005 >98%
Haloacetonitriles (HAN): Dibromoacetonitrile - 0.024 0.0006 >98%
Haloacetonitriles (HAN): Dichloroacetonitrile - 0.0096 0.0002 >98%
Haloacetonitriles (HAN): Trichloroacetonitrile - 0.015 0.0003 >98%
Haloketones (HK): 1,1-dichloro-2-propanone - 0.0072 0.0001 >99%
Haloketones (HK): 1,1,1-trichloro-2-propanone - 0.0082 0.0003 >96%
Heptachlor (H-34, Heptox) 0.0004 0.25 0.00001 >99%
Heptachlor Epoxide 0.0002 0.0107 0.0002 >98%
Hexachlorobutadiene - 0.044 0.001 >98%
Hexachlorocyclopentadiene 0.05 0.06 0.000002 >99%
Lindane 0.0002 0.055 0.00001 >99%
Methoxychlor 0.04 0.05 0.001 >99%
Pentachlorophenol 0.001 0.096 0.001 >99%
Simazine 0.004 0.12 0.004 >97%
Styrene (Vinylbenzene) 0.1 0.15 0.0005 >99%
1,1,2,2-Tetrachloroethane - 0.081 0.001 >99%
Tetrachloroethylene 0.005 0.081 0.001 >99%
Toluene 1 0.078 0.001 >99%
2,4,5-TP (Silvex) 0.05 0.27 0.0016 >99%
Tribromoacetic acid - 0.042 0.001 >98%
1,2,4-Trichlorobenzene 0.07 0.160 0.0005 >99%
1,1,1-Trichloroethane 0.2 0.084 0.0048 >95%
1,1,2-Trichloroethane 0.005 0.15 0.0005 >99%
Trichloroethylene 0.005 0.18 0.0010 >99%
Trihalomethanes (THMs): Chloroform (TTHM)** 0.080 0.300 0.015 >99.8%
Xylenes (Total) 10 0.070 0.001 >99%

*MCL values shown reflect the regulatory values referenced in the source performance data. EPA defines a Maximum Contaminant Level as the highest level of a contaminant allowed in drinking water. Current federal drinking-water standards should always be verified with the U.S. Environmental Protection Agency.

Reference: U.S. EPA - National Primary Drinking Water Regulations

NSF/ANSI 401 - Emerging Contaminants

NSF/ANSI 401 addresses emerging contaminants and incidental compounds that may occur at trace levels in drinking water, including certain pharmaceuticals, personal-care compounds, herbicides, pesticides, and other chemicals.

Reference: NSF - Emerging Contaminants and NSF/ANSI 401

Contaminant Maximum Concentration (ng/L) Minimum Percent Reduction Maximum Percent Reduction Results
Atenolol 30 ng/L 94.2% 95% Pass
Bisphenol A (BPA) 300 ng/L 98.80% 99% Pass
Carbamazepine 200 ng/L 98.6% 98.9% Pass
DEET 200 ng/L 98.7% 98.9% Pass
Estrone 20 ng/L 96.30% 97% Pass
Ibuprofen 60 ng/L 95.3% 95.4% Pass
Linuron 20 ng/L 96.6% 96.6% Pass
Meprobamate 60 ng/L 94.7% 94.7% Pass
Metolachlor 200 ng/L 98.6% 98.6% Pass
Naproxen 20 ng/L 96.3% 96.4% Pass
Nonyl phenol 200 ng/L 97.50% 97.5% Pass
Phenytoin 30 ng/L 95.50% 95.6% Pass
TCEP 700 ng/L 98% 98% Pass
TCPP 700 ng/L 97.8% 98% Pass
Trimethoprim 20 ng/L 96.7% 98% Pass

Misc. Contaminants - Fluoride Filtration Systems

Contaminant Influent Challenge Percent Reduction EPA Maximum Contaminant Level (MCL) mg/L
Fluoride (Hydrofluorosilicic Acid HFSA, FSA) 6.0 mg/L >99% 4.0

EPA reference: U.S. EPA - National Primary Drinking Water Regulations

Important Testing & Application Notes

  • Do not use a filtration system with water that is microbiologically unsafe or of unknown microbiological quality without adequate disinfection before treatment.
  • Whole-home filtration systems should be installed on the main water supply as specified for the individual system.
  • Testing was performed under laboratory conditions. Actual performance may vary based on water chemistry, contaminant levels, flow rate, system configuration, maintenance, and household usage.
  • Not all contaminants listed on this page will necessarily be present in your water.
  • Unlisted contaminants, or contaminants present at concentrations outside tested conditions, may require different or additional treatment.
STOP
Are You On Well Water?

Private or community well water should be independently tested before selecting a filtration or treatment system. Water chemistry and contaminant levels can vary significantly from one property to another. Start with testing, then choose treatment based on the actual results. Explore well water filtration systems.

How Filtration Media Performance Works

Filtration performance depends on several factors, including the type and quantity of media, available surface area, water contact time, flow rate, water chemistry, contaminant concentration, and proper system maintenance.

Freedom Water Systems uses catalytic and adsorptive filtration media selected for the water conditions and contaminants a system is designed to address. Increasing effective media contact and surface area can improve the opportunity for contaminants to be adsorbed, reduced, or otherwise treated as water passes through the system.

System selection should be based on the water source and, when appropriate, laboratory water testing rather than contaminant-reduction percentages alone.

Understanding the Performance Data

The contaminant data above includes industrial chemicals, herbicides and pesticides, pharmaceuticals, disinfection chemicals and disinfection by-products, and contaminants that may be associated with aging water-delivery systems.

A contaminant appearing in these tables does not mean it is present in every water supply. Municipal-water quality varies by utility and location, while private well water can vary from one property to another. Testing can help identify which water-quality concerns actually need treatment.

Sources & Testing References

Regulatory standards and testing protocols can change over time. The following authoritative resources provide current context for standards and regulatory values referenced on this page.

Explore Water Filtration Solutions

Performance data is one part of choosing the right water treatment system. Water source, chemistry, contaminant levels, household usage, and treatment goals should also be considered.

Contact Freedom Water Systems
www.freedomwatersystems.com
O: 702-750-9800 | M-F 8:00am-4:30pm PST
E: CustomerService@FreedomWaterSystems.com